System Parameters

Parameter Description Default Value (as of 2025-12-02)
ALM1 Process high alarm 100 2100
ALM2 Process low alarm 50 50
Hy-1 Deviation high alarm 9999 1110
Hy-2 Deviation low alarm 9999 10
Hy Hysteresis band 0.3 0.3
At Auto tuning 3 3
I Integral time 1000 900
P Proportional constant 500 500
d Derivative time 120 120
t Cycle time 2 2
Sn Input type 0 (K type TC) 0
dP Decimal point position 0 0
P-SL Display low limit -100 -100
P-SH Display high limit 2500 2500
Pb Input offset 0.0 0.0
OP-A Output mode 0 0
OUTL Output low limit 0 0
OUTH Output high limit 100 100
AL-P Alarm output definition 17 17
COOL System function selection 10 10
Addr Communication address 1 1
bAud Communication baud rate 9600 4800
FILt PV input filter 0 0
A-M Control Mode Parameter 2 2
LocK Configuration privilege 808 808
EP1-EP8 Field parameter definition nonE nonE