Manual(s) Manuals and other reference materials from the manufacturer or other sources. Model: unknown/custom electric kiln Controller: SYL-2352 Ramp and Soak PID Temperature Controller Controller manual: kiln-jewelry-SYL-2352P Manual.pdf   System Parameters Parameter Description Default Value (as of 2025-12-02) ALM1 Process high alarm 100 2100 ALM2 Process low alarm 50 50 Hy-1 Deviation high alarm 9999 1110 Hy-2 Deviation low alarm 9999 10 Hy Hysteresis band 0.3 0.3 At Auto tuning 3 3 I Integral time 1000 900 P Proportional constant 500 500 d Derivative time 120 120 t Cycle time 2 2 Sn Input type 0 (K type TC) 0 dP Decimal point position 0 0 P-SL Display low limit -100 -100 P-SH Display high limit 2500 2500 Pb Input offset 0.0 0.0 OP-A Output mode 0 0 OUTL Output low limit 0 0 OUTH Output high limit 100 100 AL-P Alarm output definition 17 17 COOL System function selection 10 10 Addr Communication address 1 1 bAud Communication baud rate 9600 4800 FILt PV input filter 0 0 A-M Control Mode Parameter 2 2 LocK Configuration privilege 808 808 EP1-EP8 Field parameter definition nonE nonE